Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cureus ; 14(2): e22484, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35371681

RESUMO

OBJECTIVE: To extend life expectancy after surgery, patients with hip fractures need to improve their mobility quickly through postoperative rehabilitation. Voluntary hip joint motion supported by the hybrid assistive limb (HAL) lumbar type, an exoskeleton robot suit characterized by its ability to detect the wearer's intentions through the bioelectrical signals and assist hip extension motions at an optimal timing, may be effective to improve mobility in patients with hip joint dysfunction after surgery. We aimed to introduce rehabilitation using the HAL lumbar type in the early period after hip fracture surgery. METHODS: Patients who underwent internal fixation for hip fracture at a single institution were prospectively enrolled. They received early postoperative rehabilitation (forward and backward bending of the lumbar spine, pelvic tilt forward and backward, standing up, and squatting) using the HAL lumbar type (six times a week for 15 min per session). Five-times-sit-to-stand (FTSS) and timed-up-and-go (TUG) tests were conducted at baseline before HAL rehabilitation (pre-HAL) and after the HAL rehabilitation (post-HAL) intervention. RESULTS: We enrolled 14 patients (one man, 13 women) in this study. There were no adverse events, and all patients were able to complete the entire rehabilitation program. Post-HAL FTSS showed significant improvement compared with pre-HAL and had a large effect size of 1.81 (95% CI = 0.93 to 2.66) and sufficient power. CONCLUSIONS: Robotic rehabilitation with HAL lumbar type could be introduced without adverse events, even in the early postoperative period following surgery for hip fracture. Further study is needed to develop an appropriate rehabilitation protocol using the HAL lumbar type.

2.
Artigo em Inglês | MEDLINE | ID: mdl-21937303

RESUMO

The electric transient response method is an effective technique to evaluate material constants of piezoelectric ceramics under high-power driving. In this study, we tried to incorporate nonlinear piezoelectric behaviors in the analysis of transient responses. As a base for handling the nonlinear piezoelectric responses, we proposed an assumption that the electric displacement is proportional to the strain without phase lag, which could be described by a real and constant piezoelectric e-coefficient. Piezoelectric constitutive equations including nonlinear responses were proposed to calculate transient responses of a piezoelectric resonator. The envelopes and waveforms of current and vibration velocity in transient responses observed in some piezoelectric ceramics could be fitted with the calculation including nonlinear responses. The procedure for calculation of mechanical quality factor Q(m) for piezoelectric resonators with nonlinear behaviors was also proposed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...